ASTM LIS Analyzer Receiver MCP Server

Let an AI agent collect and query results from clinical and laboratory analyzers (hematology, clinical chemistry, immunoassay, urinalysis, coagulation) that upload results over the standard ASTM E1381 / E1394 host interface (CLSI LIS1-A / LIS2-A2). The server acts as a small, receive-only LIS endpoint: it acknowledges the analyzer's frames, validates checksums, reassembles messages and lets the agent look results up…. Its 8 documented tools cluster into read & search, clear, reconnect.

People who work with connection and want it reachable from Claude, Cursor, VS Code, or another MCP client. The project is written in Python.

One of 32 MCP servers published from k-dense-ai/lab-instrument-mcps. Stars and repository activity are shared across all of them. See all 32 →

VERIFIED ACTIVE

LAST COMMIT 2026-09-26 · VERIFIED 2026-09-30

Apache-2.0 · Python servers · how we verify → /methodology

01 · Install ASTM LIS Analyzer Receiver

Claude Code

claude mcp add k-dense-ai-lab-instrument-mcps-servers-h -- uvx labmcp-astm-lis

Claude Desktop / Cursor / VS Code - add to config

{
  "mcpServers": {
    "k-dense-ai-lab-instrument-mcps-servers-h": {
      "command": "uvx",
      "args": [
        "labmcp-astm-lis"
      ]
    }
  }
}

Same JSON for Cursor. For VS Code, rename the top-level key from `mcpServers` to `servers`.

Using another client? Same JSON, different key

Claude Desktop · mcpServers

Cursor · mcpServers

VS Code · servers

Windsurf · mcpServers

Zed · context_servers

Cline · mcpServers

Roo Code · mcpServers

Continue · mcpServers

LibreChat · mcpServers

Gemini CLI · mcpServers

Codex CLI · mcp_servers

Full setup guides: every client.

02 · Evidence

Security posture

What to check before giving this server access to your agent - from the registry, GitHub, and our own probes. We don't score safety; we show what's verifiable.

runs as local process (stdio) - runs on your machine with your user's permissions

repo age created 2026-09-25 - young repo, little track record yet

license Apache-2.0 - declared in the repository

pypi package labmcp-astm-lis - check the name against the project README before installing (PyPI has no namespace ownership)

registry namespace io.github.K-Dense-AI is GitHub-verified and matches the repo owner

03 · What ASTM LIS Analyzer Receiver can do

Prose above is summarized from the project's README and registry record - no invented capabilities.

What you can build

g. between runs), report the analyzer link state, the messages and results received, and link-layer error counters, read received results, filtered by sample ID, patient ID, test code, time received or abnormal flag (newest last), and list the most recent ASTM messages received (newest last).

Capability map

Tools grouped from the project's README - what ASTM LIS Analyzer Receiver lets an agent do.

read & search

6 tools - e.g. Return the most recent raw commands sent to / replies received from the instrument (newest last). Useful for debugging and for recording what was done.; Report which instrument is connected (identity…

get_command_log · get_connection_info · get_connection_status · get_result_detail · get_results · list_received_messages

Clear

1 tool - e.g. Delete all received messages and results from this server's memory (e.g. between runs).

clear_results

Reconnect

1 tool - e.g. Close and re-open the connection to the instrument (e.g. after it was power cycled or a cable was re-plugged).

reconnect

Limitations (from the README)

- Receive-only. No order download, no host-query responses and no result acknowledgements beyond the link-level ACK. Query (Q) messages from the analyzer are stored and reported (kind: "query") but not answered. Order download is planned future work. - Link layer (E1381). Every frame is checked: checksum (modulo-256 sum from the frame number to ETX/ETB, as two hex digits), frame number (first frame 1, then modulo 8;

04 · Who maintains ASTM LIS Analyzer Receiver

ASTM LIS Analyzer Receiver is maintained by k-dense-ai. We track 32 MCP servers from k-dense-ai - 32 actively maintained, 9 combined GitHub stars, oldest repo from Sep 2026. Full record: all servers from k-dense-ai.

  1. Tecan Cavro Syringe Pump MCP server for Tecan Cavro syringe pumps (XLP 6000, XMP 6000, XCalibur) over the DT protocol. ★ 9
  2. Micro-Manager Microscope MCP server for microscopes controlled by Micro-Manager (pymmcore-plus). ★ 9
  3. Opentrons OT-2 / Flex MCP server for Opentrons OT-2 and Flex liquid-handling robots (HTTP API). ★ 9
  4. Atlas Scientific EZO Sensors MCP server for Atlas Scientific EZO sensor circuits (pH, ORP, DO, EC, RTD, HUM, CO2, PRS) over UART. ★ 9
  5. New Era Syringe Pump MCP server for New Era Pump Systems syringe pumps (NE-1000 family, RS-232). ★ 9
  6. Alicat Mass Flow & Pressure Controller MCP server for Alicat mass flow and pressure meters/controllers. ★ 9

05 · Facts

category
other - actively maintained as of 2026-09-30.
registry
io.github.K-Dense-AI/labmcp-astm-lis (active, first published 2026-09-26 · 4 versions)
packages
pypi:labmcp-astm-lis

06 · ASTM LIS Analyzer Receiver FAQ

Is ASTM LIS Analyzer Receiver still maintained?

Yes - as of 2026-09-30, its last commit was 2026-09-26. We re-verify nightly.

What can ASTM LIS Analyzer Receiver do?

g. between runs), report the analyzer link state, the messages and results received, and link-layer error counters, read received results, filtered by sample ID, patient ID, test code, time received or abnormal flag (newest last), and list the most recent ASTM messages received (newest last).

How do I install ASTM LIS Analyzer Receiver?

Run `uvx labmcp-astm-lis`. You can also paste the ready-made client config above.

Does ASTM LIS Analyzer Receiver run locally?

Yes - it's a stdio server: it runs on your machine (via uvx) with your user's permissions. Your data stays local unless the server itself calls external APIs.

07 · Alternatives to ASTM LIS Analyzer Receiver